Total Chlorine Water testing kit

Nuclotrasis-01-11
Product Code: NTRS-01-11
Brand: Nuclotrasis
Availability: In Stock
Rs. 6,500 Rs. 7,150
You save Rs. 650 (9% Off)

TEST METHOD FOR TOTAL CHLORINE IN INDUSTRIAL WATER  (MR: 1-200, HR: 10-200, 100-2000 & above mg/L as Cl2) 

BACKGROUND OF THE TEST: 

There are numerous applications where chlorine is dosed 

as disinfectant because it is a strong oxidizing agent and is 

considered as one of the most powerful and economical 

disinfectant at all. Consequently, chlorine residuals are 

maintained in water based on a specific application. 

Nuclotrasis offers user friendly test method with ease of 

handling the relevant reagents and other equipment in 

which the sample is first acidified and hence titrated under 

acidic conditions by an appropriate reducing agent until the 

color changes to colorless The test ideally covers the range 

as: MR: 1-200, HR: 10-200, 100-2000 & above mg/L as Cl2. 

REAGENTS/EQUIPMENTS/APPARATUS: 

• Provided 5 mL & 10 mL marked glass vial (Item 

Code: 02-01) 

• Provided MS spatula or say scoop 

• NUCLOTRASIS TOTAL CHLORINE BUFFER SOLUTION 

(Item Code: 01-11-1)

• NUCLOTRASIS TOTAL CHLORINE TEST REAGENT 

(Item Code: 01-11-2)

• NUCLOTRASIS TOTAL CHLORINE INDICATOR 

SOLUTION (Item Code: 01-11-3)

• NUCLOTRASIS TOTAL CHLORINE MR-TITRANT 

SOLUTION (Item Code: 01-11-4)

• NUCLOTRASIS TOTAL CHLORINE HR-TITRANT 

SOLUTION (Item Code: 01-11-5)

SAMPLE COLLECTION & PREPARATION 

• Make sure to immediately analyze the sample 

after collection of sample. 

• Ensure to collect sample in a suitable and 

designated bottle for a specific sample. 

• Thoroughly rinse the sample bottle with 

current sample and fill the sample by allowing 

slight overflow and immediately tighten the 

cap. 

TEST PROCEDURE: 

1. We recommend selecting the sample volume in 

the provided glass vial (Item Code: 02-01)

based on your expected/desired total chlorine 

residuals from medium range (MR) and high 

range (HR) tables below. 

Table-I: For Total Chlorine MR (1-200 & above ppm)

Range 

(mg/L as Cl2) 

Sample volume 

(mL) 

Multiplication 

Factor 

1-20 10 1

10-40 5 2

10-100 2 5

 10-200 and above 1 10

2 After required volume of sample as per 

aforementioned tables, is taken, dilute it to 50 mL

with deionized water then add 10 drops of 

NUCLOTRASIS TOTAL CHLORINE BUFFER 

SOLUTION (Item Code: 01-11-1) and swirl to mix. 

3 Then add 1 full scoop (almost 1 gm) of 

NUCLOTRASIS TOTAL CHLORINE TEST REAGENT 

(Item Code: 01-11-2) through provided spatula 

and swirl to mix. 

4 Now start adding NUCLOTRASIS Total Chlorine 

MR or HR Titrant Solution (Item Code: 01-11-4) 

drop wise with gentle mixing and while counting 

the number of drops added until the pale yellow 

color is obtained. 

5 Now add 5 drops of TOTAL CHLORINE 

INDICATOR SOLUTION (Item Code: 01-11-3). 

Consequently, dark blue color solution will 

appear. 

6 Now again start adding NUCLOTRASIS Total 

Chlorine MR or HR Titrant Solution (Item Code: 

01-11-4) drop wise with gentle mixing and while 

continue the counting with previously counted 

number of drops until colorless solution is 

obtained. 

7 Note the total number of drops added and 

multiply with multiplication factor mentioned in 

either table-I or table-II based on selected sample

range and volume. 

8 Report the final reading as required by the 

system. 

REFERENCES: 

1. Standard Methods for the Examination of Water 

and Wastewater 

 

Table-II: For Total Chlorine HR (10-2000 & above ppm)

Range 

(mg/L as Cl2) 

Sample volume 

(mL) 

Multiplication 

Factor 

10-200 10 10

20-400 5 20

50-1000 2 50

100-2000 and above 1 100


No Specifications Found